Strategic Communications and Marketing News Bureau

New buffer resists pH change, even as temperature drops

Chemistry professor Yi Lu, right, and graduate student Nathan Sieracki have developed a chemical buffer that maintains a desired pH at a range of low temperatures.

Chemistry professor Yi Lu, right, and graduate student Nathan Sieracki have developed a chemical buffer that maintains a desired pH at a range of low temperatures.

CHAMPAIGN, Ill. – Researchers at the University of Illinois have found a simple solution to a problem that has plagued scientists for decades: the tendency of chemical buffers used to maintain the pH of laboratory samples to lose their efficacy as the samples are cooled. The research team, headed by chemistry professor Yi Lu, developed a method to formulate a buffer that maintains a desired pH at a range of low temperatures.

The study appears this month in Chemical Communications.

Scientists have known since the 1930s that the pH of chemical buffers that are used to maintain the pH of lab samples can change as those samples are cooled, with some buffers raising and others lowering pH in the cooling process.

Freezing is a standard method for extending the shelf life of biological specimens and pharmaceuticals, and biological samples are routinely cooled to slow chemical reactions in some experiments. Even tiny changes in the acidity or alkalinity of a sample can influence its properties, Lu said.

“We like to freeze proteins, nucleic acids, pharmaceutical drugs and other biomolecules to keep them a long time and to study them more readily under very low temperatures using different spectroscopic techniques and X-ray crystallography,” Lu said. “But when the pH changes at low temperature, the sample integrity can change.”

Graduate student Nathan Sieracki demonstrated this by repeatedly freezing and thawing oxacillin, a penicillin analog used to treat infections.

“After one freeze-thaw 50 percent of the drug was dead in several of the buffers investigated,” Sieracki said.

Sieracki was able to demonstrate that the loss of activity was due to changes in pH and not a result of the temperature changes.

To find a buffer that would maintain a stable pH at varying temperatures, Sieracki first evaluated the behavior of several commonly used buffers over a range of temperatures. He saw that some buffers became more alkaline at lower temperatures while others grew more acidic.

These observations led to an obvious methodology: “Why don’t we just mix them together?” Sieracki said.

Little by little, he varied the proportions of the combined buffers until he found a formula that exhibited minimal pH changes at a variety of temperatures. Instead of registering changes of 2 or more pH units while cooling, which was typical of some standard buffers, the new formula changed less than 0.2 pH units during cooling, he said.

“We’re canceling out 100-fold changes in proton concentration and bringing them down within an order of magnitude,” Sieracki said.

The creation of a temperature-independent pH (TIP) buffer could have broad implications for new – and previously published – research, Lu said.

“We’re not in the business of looking at the literature and correcting other mistakes,” he said. “But some of the conclusions from previous studies could be on shaky ground if a buffer was used that changed pH dramatically at low temperatures.”

The new buffer is immediately useful for biological research, and Sieracki said he is confident that a similar buffer could be made for use in many fields, such as biochemistry, biophysics, chemical biology and biomedical research.

Lu also is affiliated with the Beckman Institute.

Editor’s note: To reach Yi Lu, call 217-333-2619; e-mail: yi-lu@illinois.edu



This article was imported from a previous version of the News Bureau website. Please email news@illinois.edu to report missing photos and/or photo credits.

Read Next

Expert Viewpoints Portrait of Siegfried Eggl.

What can researchers learn from last month’s unusual meteor activity in the US?

Last month, at least two major, but unrelated, meteor events occurred in the skies over highly populated areas of the U.S. Both fireballs, often referred to as bolides, were seen — and heard — during daylight hours, suggesting they were unusually large. University of Illinois Urbana-Champaign aerospace engineering communications coordinator Debra Levey Larson spoke with […]

Veterinary Medicine A veterinarian and a canne patient

Unlocking how dogs’ fungal ear infections evade treatment points vets to drug stewardship

Outer ear infections in dogs are very common, but are becoming resistant to topical treatment. A new study sheds light on why.

Announcements

Four Illinois students receive Goldwater scholarships

CHAMPAIGN, Ill. — One University of Illinois Urbana-Champaign sophomore and three juniors were awarded Barry M. Goldwater Scholarships for their potential to contribute to the advancement of research in the natural sciences, mathematics or engineering. Sophomore Maxwell Mamishev and juniors George Bayliss, Peter Golemis and Cliff Sun are among the 454 recipients of the $7,500 […]

Strategic Communications and Marketing News Bureau

507 E. Green St
MC-426
Champaign, IL 61820

Email: stratcom@illinois.edu

Phone (217) 333-5010