Strategic Communications and Marketing News Bureau

Crumpled graphene makes ultra-sensitive cancer DNA detector

CHAMPAIGN, Ill. — Graphene-based biosensors could usher in an era of liquid biopsy, detecting DNA cancer markers circulating in a patient’s blood or serum. But current designs need a lot of DNA. In a new study, crumpling graphene makes it more than ten thousand times more sensitive to DNA by creating electrical “hot spots,” researchers at the University of Illinois at Urbana-Champaign found.

Crumpled graphene could be used in a wide array of biosensing applications for rapid diagnosis, the researchers said. They published their results in the journal Nature Communications.

Rashid Bashir led the study.

Rashid Bashir led the study.

“This sensor can detect ultra-low concentrations of molecules that are markers of disease, which is important for early diagnosis,” said study leader Rashid Bashir, a professor of bioengineering and the dean of the Grainger College of Engineering at Illinois. “It’s very sensitive, it’s low-cost, it’s easy to use, and it’s using graphene in a new way.”

While the idea of looking for telltale cancer sequences in nucleic acids, such as DNA or its cousin RNA, isn’t new, this is the first electronic sensor to detect very small amounts, such as might be found in a patient’s serum, without additional processing.

“When you have cancer, certain sequences are overexpressed. But rather than sequencing someone’s DNA, which takes a lot of time and money, we can detect those specific segments that are cancer biomarkers in DNA and RNA that are secreted from the tumors into the blood,” said Michael Hwang, the first author of the study and a postdoctoral researcher in the Holonyak Micro and Nanotechnology Lab at Illinois.  

Graphene – a flat sheet of carbon one atom thick – is a popular, low-cost material for electronic sensors. However, nucleic-acid sensors developed so far require a process called amplification – isolating a DNA or RNA fragment and copying it many times in a test tube. This process is lengthy and can introduce errors. So Bashir’s group set out to increase graphene’s sensing power to the point of being able to test a sample without first amplifying the DNA.

Many other approaches to boosting graphene’s electronic properties have involved carefully crafted nanoscale structures. Rather than fabricate special structures, the Illinois group simply stretched out a thin sheet of plastic, laid the graphene on top of it, then released the tension in the plastic, causing the graphene to scrunch up and form a crumpled surface.

They tested the crumpled graphene’s ability to sense DNA and a cancer-related microRNA in both a buffer solution and in undiluted human serum, and saw the performance improve tens of thousands of times over flat graphene.

“This is the highest sensitivity ever reported for electrical detection of a biomolecule. Before, we would need tens of thousands of molecules in a sample to detect it. With this device, we could detect a signal with only a few molecules,” Hwang said. “I expected to see some improvement in sensitivity, but not like this.”

Narayana Aluru and his group ran simulations to figure out why crumpling graphene made it much more sensitive.

Narayana Aluru and his group ran simulations to figure out why crumpling graphene made it much more sensitive.

To determine the reason for this boost in sensing power, mechanical science and engineering professor Narayana Aluru and his research group used detailed computer simulations to study the crumpled graphene’s electrical properties and how DNA physically interacted with the sensor’s surface.

They found that the cavities served as electrical hotspots, acting as a trap to attract and hold the DNA and RNA molecules. 

“When you crumple graphene and create these concave regions, the DNA molecule fits into the curves and cavities on the surface, so more of the molecule interacts with the graphene and we can detect it,” said graduate student Mohammad Heiranian, a co-first author of the study. “But when you have a flat surface, other ions in the solution like the surface more than the DNA, so the DNA does not interact much with the graphene and we cannot detect it.”

In addition, crumpling the graphene created a strain in the material that changed its electrical properties, inducing a bandgap – an energy barrier that electrons must overcome to flow through the material – that made it more sensitive to the electrical charges on the DNA and RNA molecules.

“This bandgap potential shows that crumpled graphene could be used for other applications as well, such as nano circuits, diodes or flexible electronics,” said Amir Taqieddin, a graduate student and coauthor of the paper.

Even though DNA was used in the first demonstration of crumpled graphene’s sensitivity for biological molecules, the new sensor could be tuned to detect a wide variety of target biomarkers. Bashir’s group is testing crumpled graphene in sensors for proteins and small molecules as well.

“Eventually the goal would be to build cartridges for a handheld device that would detect target molecules in a few drops of blood, for example, in the way that blood sugar is monitored,” Bashir said. “The vision is to have measurements quickly and in a portable format.”

The National Science Foundation supported this work through the Illinois Materials Research Science and Engineering Center. Aluru and Bashir also are affiliated with the Beckman Institute for Advanced Science and Technology and the Materials Research Lab at Illinois. 

Editor’s notes: To reach Rashid Bashir, email rbashir@illinois.edu. To reach Narayan Aluru, call 217-333-1180; email aluru@illinois.edu. To reach Michael Hwang, email mth@illinois.edu.

The paper “Ultrasensitive detection of nucleic acids using deformed graphene channel field effect biosensors” is available online. DOI: 10.1038/s41467-020-15330-9

Read Next

Health and medicine Dr. Timothy Fan, left, sits in a consulting room with the pet owner. Between them stands the dog, who is looking off toward Fan.

How are veterinarians advancing cancer research in dogs, people?

CHAMPAIGN, Ill. — People are beginning to realize that dogs share a lot more with humans than just their homes and habits. Some spontaneously occurring cancers in dogs are genetically very similar to those in people and respond to treatment in similar ways. This means inventive new treatments in dogs, when effective, may also be […]

Honors From left, individuals awarded the 2025 Campus Awards for Excellence in Public Engagement are Antoinette Burton, director of the Humanities Research Institute; Ariana Mizan, undergraduate student in strategy, innovation and entrepreneurship; Lee Ragsdale, the reentry resource program director for the Education Justice Project; and Ananya Yammanuru, a graduate student in computer science. Photos provided.

Awards recognize excellence in public engagement

CHAMPAIGN, Ill. — Individuals and teams from the University of Illinois Urbana-Champaign who have made a visible impact on society were recently recognized with the 2025 Campus Awards for Excellence in Public Engagement. Faculty, staff members, students and community members who engage the public to address critical civic and community issues at the local, state, […]

Uncategorized Portrait of the researchers standing outside in front of a grove of trees.

Study links influenza A viral infection to microbiome, brain gene expression changes

CHAMPAIGN, Ill. — In a study of newborn piglets, infection with influenza A was associated with disruptions in the piglets’ nasal and gut microbiomes and with potentially detrimental changes in gene activity in the hippocampus, a brain structure that plays a central role in learning and memory. Maternal vaccination against the virus during pregnancy appeared […]

Strategic Communications and Marketing News Bureau

507 E. Green St
MC-426
Champaign, IL 61820

Email: stratcom@illinois.edu

Phone (217) 333-5010